previous next Up Title Contents

Tests/Segmented_Mode/ParFiles/BM


Carney1k.par
	4			Order for the gamma tone filters - BM model.
	single		Centre frequency mode for filter.
	1000.0		Initial centre frequency of gamma-tone filter bank.
	1100		Cut-off frequency for OHC low-pass filter, Fc (Hz).
	5000		Operating point of OHC (feedback) non-linearity, P_Dfb (Pa).
	0.462		Asymmetrical bias for OHC non-linearity, P0 (rad).
	10.0		Maximum depolarising hair cell voltage, Vmax (V).
	
	

Carney4k.par
	4			Order for the gamma tone filters - BM model.
	single		Centre frequency mode for filter.
	4000.0		Initial centre frequency of gamma-tone filter bank.
	1100		Cut-off frequency for OHC low-pass filter, Fc (Hz).
	5000		Operating point of OHC (feedback) non-linearity, P_Dfb (Pa).
	0.462		Asymmetrical bias for OHC non-linearity, P0 (rad).
	10.0		Maximum depolarising hair cell voltage, Vmax (V).
	
	

CookeAMP1k.par
	single		Centre frequency mode for filter.
	1000.0		Initial centre frequency of gamma-tone filter bank.
	ERB			Band width (3 dB down) mode for filters.
	1.019		ERB Bandwidth correction 4th order.
	AMP			Output option (BM, POW, AMP). 
	

CookeBM4k.par
	single		Centre frequency mode for filter.
	4000.0		Initial centre frequency of gamma-tone filter bank.
	ERB			Band width (3 dB down) mode for filters.
	1.019		ERB Bandwidth correction 4th order.
	BM			Output option (BM, POW, AMP). 
	

DRNL18k.par
	4		Total order for the gamma tone filters - BM model.
	single	Frequency mode.
	18000	Centre frequency of gamma-tone filter for basilar membrane.
	Nonlinear	Band width (3 dB down) mode for filters.
	1.0		Narrow filter broadening coefficient.
	20.0	Threshold above which compression takes place (dB SPL).
	0.66	Compression ratio.
	1.0		Wide filter broadening coefficient.
	2.5		Narrow filter low-pass cut-off scale.
	

DRNL1k.par
	4		Total order for the gamma tone filters - BM model.
	single	Frequency mode.
	1000	Centre frequency of gamma-tone filter for basilar membrane.
	Nonlinear	Band width (3 dB down) mode for filters.
	1.0		Narrow filter broadening coefficient.
	20.0	Threshold above which compression takes place (dB SPL).
	0.66	Compression ratio.
	1.0		Wide filter broadening coefficient.
	2.5		Narrow filter low-pass cut-off scale.
	

DRNL4k.par
	4		Total order for the gamma tone filters - BM model.
	single	Frequency mode.
	4000	Centre frequency of gamma-tone filter for basilar membrane.
	Nonlinear	Band width (3 dB down) mode for filters.
	1.0		Narrow filter broadening coefficient.
	20.0	Threshold above which compression takes place (dB SPL).
	0.66	Compression ratio.
	1.0		Wide filter broadening coefficient.
	2.5		Narrow filter low-pass cut-off scale.
	

DRNLT8k.par
	4		Total order for the gamma tone filters - BM model.
	single	Frequency mode.
	8000.0	Centre frequency of gamma-tone filter for basilar membrane.
	user	Band width (3 dB down) mode for filters.
	1343	Bandwidth (Hz).
	1.0		Narrow filter broadening coefficient.
	20.0		Threshold above which compression takes place (dB SPL).
	0.63	Compression ratio.
	5453	Wide filter Centre Frequency (Hz).
	1823	Wide filter band width (Hz).
	-25.95	Wide filter attenuation (dB SPL).
	2.5		Narrow filter low-pass cut-off scale.
	

GammaT4k.par
	4			Order for the gamma tone filters - basilar membrane model.
	single		Centre frequency mode for filter.
	4000.0		Initial centre frequency of gamma-tone filter bank.
	ERB			Band width (3 dB down) mode for filters.
	


previous next Up Title Contents